PRODUCTS
- Pressure measurement
- Thermometers & Temperature Sensors
- Flowmeters
- Level measurement
- Pulse Radar Level Transmitter
- Guided Wave Radar Level Transmitters
- Magnetostrictive Level Transmitter
- Ultrasonic Level Transmitters
- Level Gauge
- Capacitance Level Transmitter
- Magnetic Level Transmitter
- Hydrostatic pressure level transmitters
- Level Switch
- DISPLACER TYPE MAGNETIC LEVEL SWITCH - DSI
- Compact Displacer Level Switch for Water †CDSI
- VERTICAL LEVEL CONTROL - VLCI
- CHAMBER FLOAT MAGNETIC LEVEL SWITCH – CFSI
- Top Mounted Direct Insert Type
- Side Mounted Direct Insert Type
- External Cage Chamber SMLS/2000
- External Cage Chamber - TMLS/2000
- Top Mounted Float Operated-TMLS/4000
- Top Mounted Displacer Operated TMLS/3000
- Table instruments
- Supervision Software
- Industrial automation
- Calibration
- Accessories
External Cage Chamber - TMLS/2000
Serie:TMLS/2000
Prisma Instruments offers External Cage Type Level Switches for single level set point. This is trouble free, consistent and inexpensive solution to control Level in the tanks / vessels. GIC offers following Series of External Cage Chamber Type Level Switches:
- Series TMLS/2000
- Series SMLS/2000
Â
External Cage Chamber: Series TMLS/2000
This type of level switch assembly is mounted vertically on the external cage as shown in figure. The external cage type level switch is mounted outside the tank / vessel which significantly reduces effect of turbulence.
Â
- Features
- Datasheet
- Informations
Spécifications
|
|
Type |
External Cage Chamber |
Series |
SMLS/2000 TLMS/2000 |
Float MOC |
SS 304, SS 304L, SS 316, SS 316L, Monel, Titanium, Inconel 600, Hastelloy C, others on request |
Float Stem MOC |
SS 304, SS 304L, SS 316, SS 316L, Monel, Titanium, Inconel 600, Hastelloy C, others on request |
Switch Type |
Snap Acting 1 SPDT / 2 SPDT Microswitch, 5A, 230 VAC |
Switch Housing |
Die Cast Aluminium Weatherproof to IP - 65 Die Cast Aluminium Explosion proof suitable for Group IIA, IIB Die Cast Aluminium Explosion proof suitable for Group IIC |
Electrical Connection |
¾"ET(F) |
External Cage Chamber |
CS, SS 304, SS 304L, SS 316, SS 316L, Monel, Titanium, Inconel, Hastelloy C etc. |
Centre To Centre Distance |
250 mm (Standard) |
Process Connection |
Flanged in various sizes |
Minimum Specific Gravity |
0.8, others on request |
Maximum Pressure |
Up to 20 Kg/cm at ambient temperature, others on request |
Maximum Temperature |
Up to 150°C, others on request |
Download the datasheet (PDF External Cage Chamber TMLS/2000)