Integral Meter Run Assembly
Integral Meter Run Assembly
Integral Flow Orifice Assembly is used Differential Pressure Transmitter has to be directly mounted on the orifice assembly. This eliminates cost of installation of Differential Pressure Transmitter with impulse piping up to the orifice assembly. The transmitter is mounted on the orifice assembly through a 3/5 Valve H-type manifold. Available with line sizes of 2" & below. However due to process temperature limits of the transmitter, this assembly cannot be used for process temperatures above 120 Degrees Centigrade. The assembly consists of a orifice plate between two integral blocks having corner tap. Generally meter run pipe is recommended with upstream length of 750mm and downstream length of 250mm. The pipes are welded to the blocks with end flange.
Â
Advantages of using Integral Meter run assembly
- Use of an integral orifice flow meter will eliminate the three measurement inaccuracies recorded in small orifice line installations.
- The Integral Orifice honed body reduces ID uncertainty
- By inserting precision bored upstream and downstream sections of pipe, the velocity profile distortion due to pipe roughness is reduced.
- The self-centering design of the Integral Orifice Plate eliminates plate misalignment.
Improves reliability and maintenance costs
The integral orifice flow meter eliminates impulse lines, reducing leak points by over 50% and decrease start-up time due to the flexibility of numerous process connection options. The direct mount design minimizes line plugging by eliminating long lines, small-bore ports, and crevices while providing consistently reliable installations.
Â
- Accuracy up to ±0. 5% of volumetric flow rate
- Integral manifold head allows direct mounting of DP transmitters
- Ideal fluid types: liquid, gas, and steam
Â
Â
Â
- Features
- Datasheet
- Informations
Spécifications
|
|
Design |
Conforms to ISA RP 3.2 , DIN 1952 , BS 1042, ISO-5167 |
Types |
Square edge concentric, Quadrant edged, Conical entrance, Eccentric, Segmental |
Plate material |
SS304 , SS316 , SS316L as standard. Hastelloy-C , Monel , PP , PVC , PTFE coated , etc. can be given on request. |
Orifice Bore |
In accordance with ISO-5167, BS-1042, ASME MFC 3M, R.W.Miller, L.K.Spink, AGA-3 |
Tab Plate |
In the same material as plate & is welded to orifice plate. Tab plate integral to the Orifice plate (i.e. without welding) can also be offered as a special case. |
Vent / Drain |
Vent or Drain holes are provided as per customer's requirement. The diameter of the vent or drain holes are as per ISA RP 3.2 |
Flange Union | Weld neck, Slip on, Threaded, Socket welded with RF or RTJ facing Orifice flanges are in accordance with ANSI B16.36 with minimum flange rating of 300# for sizes up to 8" or male - female flanges in accordance with ANSI B16.5 |
Pressure Tappings |
Corner tappings are recommended for sizes upto 1 ½"; Flange taps from 2" to 16" ; D - D/2 taps for higher sizes |
Gasket |
CAF as per IS: 2712 Gr 0/1 , SS spiral wound + CAF , SS spiral wound + Grafoil, SS spiral wound + PTFE are normally supplied as per process requirement. Other materials available on request. For RTJ flanges , the plate is fixed on the plate holder. The plate holder is in Soft Iron material & acts as a gasket. Â |
Studs / Nuts | ASTM A193 Gr.B7/A-194 Gr.2H as standard, Other material on request. |
Jack Screw | ASTM A193 Gr.B7/A-194 Gr.2H as standard, Other material on request. |